Model Number Rated Load (psi) Gauge Dia. (in) Thread (Lower) Number Intervals Major Grad. Minor Grad. Accuracy Gauge Type Gauge Adapter
HA-77 5 & 10 Ton / 0-10,000 psi 4 1/2 1/2" NPTF 1 Ton / 1000 psi 1 Ton / 1000 psi 200 lbs / 200 psi +/- .5% Dry HA-58 (5 1/2") or HA-16 (3")
HA-75 20 & 30 Ton / 0-10,000 psi 4 1/2 1/2" NPTF 5 Ton / 1000 psi 5 Ton / 1000 psi 1 Ton / 200 psi +/- 5% Dry HA-58 (5 1/2") or HA-16 (3")
HA-76 50 & 100 Ton / 0-10,000 psi 4 1/2 1/2 NPTF 10 Ton / 1000 psi 10 Ton / 1000 psi 2 Ton / 200 psi +/- .5% Dry HA-58 (5 1/2") or HA-16 (3")
HA-76-1 75 Ton / 10,000 psi 2 1/2 1/4" NPTF 7, 5 Ton / 1000 psi 7, 5 Ton / 1000 psi 1, 5 Ton / 200 psi +/- .5% Dry HA-91
HA-40-1 0-10,000 psi 4 1/2 1/2" NPTF 1000psi 500psi 100psi +/- .5% Dry HA-58 (5 1/2") or HA-16 (3")
HA-90 0-10,000 psi 2 1/2 1/4" NPTF 2500 psi 2500 psi 500 psi +/- .2% Liquid HA-91